ATV212HD11M3X
variable speed drive, Altivar 212, 11kW, 15hp, 240V, 3 phases, without EMC, IP21
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| Prospective Line Isc | 22 kA |
| Electrical Connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3 |
| Network Frequency | 47.5...63 Hz |
| Discrete Input Logic | positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V |
| Type Of Cable | without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC |
| Height | 330 mm |
| Acceleration And Deceleration Ramps | automatic based on the load || linear adjustable separately from 0.01 to 3200 s |
| Analogue Output Type | FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits |
| Speed Drive Output Frequency | 0.5-200 Hz |
| Discrete Output Type | configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles |
| Transmission Frame | RTU |
| Torque Accuracy | +/- 15 % |
| Asynchronous Motor Control Profile | flux vector control without sensor, standard || voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f |
| Maximum Switching Current | 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) |
| Communication Service | read device identification (43) || monitoring inhibitable || read holding registers (03) 2 words maximum || write multiple registers (16) 2 words maximum || write single register (06) || time out setting from 0.1 to 100 s |
| Transient Overtorque | 120-120 % of nominal motor torque +/- 10 % 60 s |
| Insulation Resistance | >= 1 mOhm 500 V DC for 1 minute |
| Response Time | FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete |
| Data Format | 8 bits, 1 stop, odd even or no configurable parity |
| Apparent Power | 17.6 kVA 240 V |
| Dielectric Strength | 2830 V DC between earth and power terminals || 4230 V DC between control and power terminals |
| Power Range | 7-11 kW 200-240 V 3 phase |
| Net Weight | 11.55 kg |
| Type Of Polarization | no impedance |
| Frequency Resolution | display unit 0.1 Hz || analog input 0.024/50 Hz |
| Accuracy | +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C |
| Switching Frequency | 6...16 kHz adjustable || 12...16 kHz with derating factor |
| Maximum Transient Current | 50.8 A 60 s |
| Connector Type | 1 open style || 1 RJ45 |
| Analogue Input Number | 2 |
| Motor Slip Compensation | automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control |
| Motor Starter Type | variable speed drive |
| Discrete Output Number | 2 |
| Minimum Switching Current | 3 mA 24 V DC configurable relay logic |
| Analogue Output Number | 1 |
| Physical Interface | 2-wire RS 485 |
| Power Dissipation In W | 459 W |
| Continuous Output Current | 46.2 A 230 V |
| Number Of Addresses | 1-247 |
| Tightening Torque | 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 4.5 N.m, 40 lb.in L1/R, L2/S, L3/T) |
| Discrete Input Type | F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm |
| Speed Range | 1-10 |
| Isolation | electrical between power and control |
| Local Signalling | for DC bus energized 1 LED (red) |
| Linearity Error | VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output |
| Specific Application | HVAC |
| Output Voltage | <= power supply voltage |
| Nominal Switching Frequency | 12 kHz |
| Width | 245 mm |
| Transmission Rate | 9600 bps or 19200 bps |
| Braking To Standstill | by DC injection |
| Air Flow | 157 m3/h |
| Depth | 190 mm |
| Protection Type | overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor |
| Supply | internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
| Analogue Input Type | VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits |
| Discrete And Process Manufacturing | building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump |
| Sampling Duration | 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog |
| Speed Accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Option Card | communication card LonWorks |
| Product Destination | asynchronous motors |
| Range Of Product | Altivar 212 |
| Product Or Component Type | variable speed drive |
| Ip Degree Of Protection | IP21 |
| Motor Power Kw | 11 kW |
| Phase | 3 phase |
| Line Current | 34.4 A 240 V || 42.1 A 200 V |
| [Us] Rated Supply Voltage | 200...240 V - 15...10 % |
| Communication Port Protocol | Modbus || LonWorks || METASYS N2 || BACnet || APOGEE FLN |
| Supply Voltage Limits | 170-264 V |
| Product Specific Application | pumps and fans in HVAC |
| Emc Filter | without EMC filter |
| Maximum Horse Power Rating | 15 hp |
| Device Short Name | ATV212 |
| Supply Frequency | 50...60 Hz - 5...5 % |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews