6SL32201YE640CB0
SIEMENS
G120X IP20 380...480V 500kW FSJ C3
AVAILABLE
GET A QUOTE NOW
- "SINAMICS G120X Rated power: 500 kW at 135% 3 sec or 110% 60 sec. 100% 240 sec; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 \u00b0C Size: FSJ Degree of protection IP20 / UL open type Without operator panel Without IO expansion Integrated fieldbus: MODBUS RTU. BACnet MS/TP.USS"
| Specification | Value |
|---|---|
| Depth | 393 mm |
| Width | 801 mm |
| Height | 1621 mm |
| Mains voltage | 380 V |
| Country of Origin | DE |
| Mains frequency | 50/60 Hz |
| Number of phases input | 3 |
| With PC connection | false |
| Number of phases output | 3 |
| Number of digital inputs | 6 |
| Max. output frequency | 100 Hz |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 1 |
| With optical interface | false |
| Number of HW-interfaces USB | 0 |
| Type of converter | U converter |
| Degree of protection (IP) | IP20 |
| Nominal output current I2N | 910 A |
| Number of HW-interfaces other | 6 |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces RS-232 | 1 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Supporting protocol for ASI | false |
| Supporting protocol for CAN | false |
| Supporting protocol for KNX | false |
| Supporting protocol for LON | false |
| Number of HW-interfaces parallel | 0 |
| 4-quadrant operation possible | false |
| Supporting protocol for MODBUS | true |
| Integrated breaking resistance | false |
| Number of HW-interfaces serial TTY | 5 |
| Supporting protocol for SERCOS | false |
| Supporting protocol for TCP/IP | false |
| Supporting protocol for SUCONET | false |
| Supporting protocol for INTERBUS | false |
| Supporting protocol for PROFIBUS | false |
| Supporting protocol for DeviceNet | false |
| Supporting protocol for PROFIsafe | false |
| Supporting protocol for EtherNet/IP | false |
| Supporting protocol for PROFINET IO | false |
| Supporting protocol for SafetyBUS p | false |
| Supporting protocol for Data-Highway | false |
| Supporting protocol for PROFINET CBA | false |
| Application in industrial area permitted | true |
| Number of HW-interfaces industrial Ethernet | 0 |
| Relative symmetric net frequency tolerance | 5 % |
| Relative symmetric net voltage tolerance | -10 % |
| Supporting protocol for INTERBUS-Safety | false |
| Supporting protocol for DeviceNet Safety | false |
| Supporting protocol for other bus systems | true |
| Supporting protocol for Foundation Fieldbus | false |
| Max. output at linear load at rated output voltage | 400 kW |
| Supporting protocol for AS-Interface Safety at Work | false |
| Max. output at quadratic load at rated output voltage | 500 kW |
| Application in domestic- and commercial area permitted | false |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews