RGF26160
Schneider Electric
Circuit breaker, PowerPacT R, 1600A, 2 pole, 600VAC, 18kA, busbar, ET 1.0I, 80%
Dostępny
Uzyskaj wycenę już teraz
- "PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked."
| Specification | Value |
|---|---|
| Circuit Breaker Application | HACR rated |
| Mounting Mode | unit mount busbar) |
| Network Frequency | 50/60 Hz |
| Wire Stripping Length | 35 mm |
| Terminal Identifier | AL2500RK |
| Utilisation Category | category A |
| Line Rated Current | 1600-1600 A |
| [Ics] Rated Service Breaking Capacity | 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2 |
| Trip Unit Technology | electronic, basic, ET 1.0I, I |
| Trip Unit Name | ET 1.0I |
| Height | 16.24 in |
| Continuous Current Rating | 80 % |
| Breaking Capacity | AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2 |
| [Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
| Suitability For Isolation | yes IEC 60947-2 |
| [Ue] Rated Operational Voltage | 600 V AC 50/60 Hz UL 489 |
| Tightening Torque | 62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil) |
| Mounting Support | busbar |
| Breaking Capacity Code | G |
| Magnetic Tripping Current | 2400-19200 A |
| Poles Description | 2P |
| Local Signalling | trip indicator |
| Quantity Per Set | 1 |
| Number Of Slots | 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in) |
| Awg Gauge | AWG 3/0...750 kcmil aluminium/copper |
| Width | 16.53 in |
| Electrical Connection | busbar connection, line || busbar connection, load |
| Depth | 14.49 in |
| Net Weight | 52 lb(US) |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
| Control Type | operating handle |
| Product Or Component Type | circuit breaker |
| Product Name | PowerPact R |
| Device Application | distribution |
| Range | PowerPact |
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.
„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
W razie potrzeby dostępne są również standardowe opcje dostawy.
„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
1
Step 1
Część dodana do zapytania
2
Krok 2
Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.
3
Krok 3
Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.
4
Krok 4
Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.
Google Reviews