LU2B32B

Schneider Electric

Reversing power base, TeSys Ultra, 3P, 32A/690V, coil 24VAC

Dostępny

Uzyskaj wycenę już teraz

  • "TeSys U standard reversing power base, 3 poles (3NO), rated 32A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a \"all in one\" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0B to be supplied with 24V AC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
Więcej informacji arrow Czytaj mniej arrow
Specification Value
Product Certifications CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Height 224 mm
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate 3600 cyc/h
Connections - Terminals control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² rigid || power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end
Net Weight 1.27 kg
Fixing Mode clipped DIN rail) || screw-fixed plate)
[Uimp] Rated Impulse Withstand Voltage 6 kVIEC 60947-6-2
Inrush Restraint Duration 25 ms AC 50/60 Hz
Standards EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Typical Current Consumption 2360 mA 24 V AC I maximum while closing
Mechanical Durability 15 Mcycles
Compatibility Code LU2B
Operating Time 150 ms with change of direction power circuit || 35 ms opening control circuit || 70 ms closing control circuit || 75 ms without change of direction power circuit
Width 45 mm
Tightening Torque control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
Safe Separation Of Circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Depth 126 mm
Heat Dissipation 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM
[Ics] Rated Service Breaking Capacity 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
[Ue] Rated Operational Voltage 690 V AC power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Uc] Control Circuit Voltage 24 V AC 50/60 Hz
Product Or Component Type reversing power base
[Ith] Conventional Free Air Thermal Current 32 A
Product Name TeSys Ultra
Range TeSys
Utilisation Category AC-43 || AC-44 || AC-41
[Ie] Rated Operational Current 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V
Suitability For Isolation yes
Product Compatibility control unit LUC.X6B || control unit LUC.1XB || control unit LUC.05B || control unit LUC.12B || control unit LUC.18B || control unit LUC.32B
Auxiliary Contacts Type linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
Poles Description 3P
Control Circuit Voltage Limits 14.5 V AC drop-out || 20...26.5 V AC in operation
Network Frequency 40...60 Hz
Device Application motor control || motor protection
Device Short Name LU2B
Więcej informacji arrow Czytaj mniej arrow
*Nowe produkty są objęte 24-miesięczną gwarancją Obso.
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.


„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
*Dostawa i odbiór tego samego i następnego dnia są dostępne dla towarów z naszych oddziałów w Wielkiej Brytanii i Holandii. Odbiór następnego dnia i dostawa w ciągu 2 dni są dostępne dla towarów pochodzących od naszych partnerów. W 90% przypadków możemy dostarczyć towar szybciej niż przewidywany czas dostawy producenta.

W razie potrzeby dostępne są również standardowe opcje dostawy.


„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
Posiadamy akredytację ISO 9001, dzięki czemu możesz być spokojny o swój zakup.

Co mówią o nas nasi klienci

Trustpilot

1

Step 1

    Część dodana do zapytania

    2

    Krok 2

    Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.

    3

    Krok 3

    Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.

    4

    Krok 4

    Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.