LTMR08CFM

Schneider Electric

Motor controller, TeSys T, Motor Management, CANopen, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC

Dostępny

Uzyskaj wycenę już teraz

  • "TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus\u2122, CANopen, DeviceNet\u2122, Profibus\u2122, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses CANopen as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg."
Więcej informacji arrow Czytaj mniej arrow
Specification Value
Contacts Type And Composition 1 NO + 1 NC fault signal || 3 NO
Height 61 mm
Connection Pitch 5.08 mm
Permissible Power 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Network And Machine Diagnosis Type event recording || trip history information || phase fault and earth fault trip counters || trip context information || waiting time after overload tripping || remaining operating time before overload tripping || running hours counter/operating time || motor control command recording || starting current and time || fault recording
Pollution Degree 3
Logic Input Number 6
Maximum Operating Rate 1800 cyc/h
Connections - Terminals control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
Input Current 3.1 mA 100 V || 7.5 mA 240 V
Current State 1 Guaranteed logic input 79...264 V >= 2 mA 25 ms
Net Weight 0.53 kg
[Uimp] Rated Impulse Withstand Voltage 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Associated Fuse Rating 4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibility electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Current State 0 Guaranteed logic input 0...40 V <= 15 mA 25 ms
[Ui] Rated Insulation Voltage 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Short-Circuit Withstand 100 kA conforming to EN/IEC 60947-4-1
Compatibility Code LTMR
Protection Type power factor variation || reverse polarity protection || thermal protection || phase failure || load fluctuation || overload || phase unbalance || thermal overload protection || overload (long time) || locked rotor || earth-leakage protection
Web Services web server
Width 91 mm
Load Current 5 A 250 V AC logic output || 5 A 30 V DC logic output
Tightening Torque control circuit 0.5-0.6 N.m flat 3 mm
Overvoltage Category III
Depth 122.5 mm
Maximum Operating Frequency 2 Hz
Metering Type temperature || phase current I1, I2, I3 RMS || imbalance current || average current Iavg || earth-fault current
Product Or Component Type motor controller
Product Name TeSys T
Measurement Current 0.4-8 A
Range TeSys
Current Consumption 8...62.8 mA
[Us] Rated Supply Voltage 100...240 V AC 50/60 Hz
Communication Port Protocol CANopen
Bus Type CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable || CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable
Supply Voltage Limits 93.5-264 V AC
Device Application equipment monitoring and control
Device Short Name LTMR
Więcej informacji arrow Czytaj mniej arrow
*Nowe produkty są objęte 24-miesięczną gwarancją Obso.
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.


„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
*Dostawa i odbiór tego samego i następnego dnia są dostępne dla towarów z naszych oddziałów w Wielkiej Brytanii i Holandii. Odbiór następnego dnia i dostawa w ciągu 2 dni są dostępne dla towarów pochodzących od naszych partnerów. W 90% przypadków możemy dostarczyć towar szybciej niż przewidywany czas dostawy producenta.

W razie potrzeby dostępne są również standardowe opcje dostawy.


„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
Posiadamy akredytację ISO 9001, dzięki czemu możesz być spokojny o swój zakup.

Co mówią o nas nasi klienci

Trustpilot

1

Step 1

    Część dodana do zapytania

    2

    Krok 2

    Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.

    3

    Krok 3

    Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.

    4

    Krok 4

    Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.