DPE50BD
Schneider Electric
IEC contactor,Easy TeSys DPE,nonreversing,50A,3P,30HP at 480V AC,24VDC coil
Dostępny
Uzyskaj wycenę już teraz
- "Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3 (30HP@480V). It provides a 24V DC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| [Uc] Control Circuit Voltage | 24 V DC |
| Auxiliary Contact Composition | 1 NO |
| Contactor Application | motor control || resistive load |
| Product Or Component Type | contactor |
| Product Name | Easy TeSys DPE |
| Range | Easy TeSys |
| Pole Contact Composition | 3 NO |
| Utilisation Category | AC-1 || AC-3 |
| [Ie] Rated Operational Current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Poles Description | 3P |
| Maximum Horse Power Rating | 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Motor Power Kw | 15 kW 220...230 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz |
| Device Short Name | DPE |
| Minimum Switching Current | 5 mA for signalling circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC |
| Height | 122 mm |
| Power Dissipation Per Pole | 3.7 W AC-3 || 9.6 W AC-1 |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Control Circuit Voltage Limits | drop-out: 0.1...0.3 Uc (at <60 °C) || operational: 0.75...1.25 Uc (at <60 °C) |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit || 60 A (at 60 °C) for power circuit |
| Mounting Support | rail || plate |
| Control Circuit Type | DC 50/60 Hz |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Hold-In Power Consumption In W | 7.4-7.4 W 20 °C |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Rated Breaking Capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947 |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit |
| Connections - Terminals | power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw connection 2 2.5-10 mm² - cable stiffness: flexible with cable end || power circuit: screw connection 1 2.5-25 mm² - cable stiffness: solid without cable end || power circuit: screw connection 2 2.5-16 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end |
| Coil Technology | without built-in suppressor module |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Signalling Circuit Frequency | 25...400 Hz |
| Tightening Torque | power circuit 7 N.m screw connectors 16-25 mm² hexagonal 4 mm || power circuit 5 N.m screw connectors 2.5-16 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 |
| Electrical Durability | 0.6 Mcycles 60 A AC-1 <= 440 V || 1 Mcycles 40 A AC-3 <= 440 V |
| Mechanical Durability | 5 Mcycles |
| Inrush Power In W | 19-19 W 20 °C) |
| Auxiliary Contacts Type | mechanically linked 1 NO IEC 60947-5-1 |
| Operating Time | 4...19 ms opening || 12...26 ms closing |
| Width | 55 mm |
| Depth | 122 mm |
| [Icw] Rated Short-Time Withstand Current | 400 A 40 °C - 10 s for power circuit || 810 A 40 °C - 1 s for power circuit || 84 A 40 °C - 10 min for power circuit || 208 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit |
| Heat Dissipation | 4-5 W 50/60 Hz |
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.
„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
W razie potrzeby dostępne są również standardowe opcje dostawy.
„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
1
Step 1
Część dodana do zapytania
2
Krok 2
Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.
3
Krok 3
Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.
4
Krok 4
Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.
Google Reviews






