TM3TM3G

Schneider Electric

analog IO module, Modicon TM3, 2 analog or temperature inputs, 1 analog output, spring, 24V DC

Disponibile

Richiedi un preventivo adesso

  • "This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue I/O module provides 2 inputs, 1 output with 16bit, 15bit + sign input resolution. It is an I/O module with a rated supply voltage of 24V DC, a current consumption of 60mA, 55mA at 5V DC via bus connector, 55mA, 80mA at 24V DC via external supply. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between input and supply at 1500V AC, input and internal logic at 500V AC, output and supply at 1500V AC and output and internal logic at 500V AC. It is furnished with removable spring terminal for electrical connection with 5.08mm pitch adjustment for inputs, outputs and supply. It is an IP20 rated product. Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.1kg. This product is certified by CE. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers."
Per saperne di più arrow Weniger lesen arrow
Specification Value
Electrical Connection 11 x 2.5 mm² removable spring terminal block pitch 5.08 mm for inputs, outputs and supply
Height 90 mm
Input Impedance <= 50 Ohm current || >= 1 MOhm voltage || >= 1 MOhm thermocouple || >= 1 MOhm temperature probe
Load Type resistive
Type Of Cable twisted shielded pairs cable <30 m input/output
Non-Linearity +/- 0.01 %FS analog output || +/- 0.1 %FS analog input
Lsb Value 0.15 mV 0...10 V voltage || 0.30 mV - 10...10 V voltage || 0.30 µA 0...20 mA current || 0.244 µA 4...20 mA current || 0.1 °C temperature probe || 0.1 °C thermocouple || 2.44 mV 0...10 V voltage || 4.88 mV - 10...10 V voltage || 4.88 µA 0...20 mA current || 3.91 µA 4...20 mA current
Permissible Continuous Overload 13 V voltage || 40 mA current
Marking CE
Analogue Input Resolution 16 bits || 15 bits + sign
Net Weight 0.1 kg
Absolute Accuracy Error +/- 6 °C at 25 °C for thermocouple R, S 0...200 °C || +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C || +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C || +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C || +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C || +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C || +/- 0.1 % of full scale at 25 °C for analogue input voltage/current || +/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C || +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe || +/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C || +/- 0.1 % of full scale at 25 °C for thermocouple B 300...1820 °C || +/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C || +/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C || +/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C || +/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C || +/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C || +/- 0.1 % of full scale at 25 °C for analogue output voltage/current
Current Consumption 55 mA 24 V DC via external supply no load || 55 mA 5 V DC via bus connector no load || 60 mA 5 V DC via bus connector full load || 80 mA 24 V DC via external supply full load
Conversion Time 100 ms + 100 ms per channel + 1 controller cycle time thermocouple || 100 ms + 100 ms per channel + 1 controller cycle time temperature probe || 10 ms + 10 ms per channel + 1 controller cycle time voltage/current
Analogue Output Resolution 12 bits
Temperature Drift +/- 0.006 %FS/°C
Supply Voltage Limits 20.4-28.8 V
Stabilisation Time 1 ms
Load Impedance Ohmic 1 kOhm voltage || 300 Ohm current
Output Ripple 20 mV
Mounting Support top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Local Signalling for PWR 1 LED (green)
Surge Withstand 1 kV power supply common mode IEC 61000-4-5 || 0.5 kV power supply differential mode IEC 61000-4-5 || 1 kV I/O common mode IEC 61000-4-5 || 0.5 kV I/O differential mode IEC 61000-4-5
Cross Talk <= 1 LSB
Width 23.6 mm
Depth 70 mm
[Us] Rated Supply Voltage 24 V DC
Insulation between input and supply 1500 V AC || between input and internal logic 500 V AC || between output and supply 1500 V AC || between output and internal logic 500 V AC
Sampling Duration 10 ms voltage/current || 100 ms voltage/current || 100 ms thermocouple || 100 ms temperature probe
Repeat Accuracy +/-0.5 %FS input || +/- 0.4 %FS output
Range Of Product Modicon TM3
Analogue Output Type current 4...20 mA || current 0...20 mA || voltage 0...10 V || voltage - 10...10 V
Product Or Component Type input/output analog module
Analogue Input Number 2
Analogue Output Number 1
Range Compatibility Modicon M221 || Modicon M241 || Modicon M251 || Modicon M262
Analogue Input Type current 4...20 mA || current 0...20 mA || voltage 0...10 V || voltage - 10...10 V || thermocouple - 200...1000 °C thermocouple J || thermocouple - 200...1300 °C thermocouple K || thermocouple 0...1760 °C thermocouple R || thermocouple 0...1760 °C thermocouple S || thermocouple 0...1820 °C thermocouple B || thermocouple - 200...400 °C thermocouple T || thermocouple - 200...1300 °C thermocouple N || thermocouple - 200...800 °C thermocouple E || thermocouple 0...2315 °C thermocouple C || Ni 100/Ni 1000 temperature probe - 60...180 °C || Pt 100 temperature probe - 200...850 °C || Pt 1000 temperature probe - 200...600 °C
Per saperne di più arrow Weniger lesen arrow
*Gli articoli nuovi sono coperti da una garanzia Obso di 24 mesi.
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.


“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
*La consegna e il ritiro il giorno stesso e successivo sono disponibili per le scorte delle nostre filiali nel Regno Unito e in Olanda. La consegna e il ritiro il giorno successivo e la consegna in 2 giorni sono disponibili per le scorte acquistate dai nostri partner. Nel 90% dei casi, se necessario, possiamo consegnare più velocemente del tempo previsto dal produttore.

Se necessario, sono disponibili anche opzioni standard per la consegna.


“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
Siamo accreditati ISO 9001 per garantire la tranquillità del vostro acquisto.

Cosa dicono di noi i nostri clienti

Trustpilot

1

Step 1

    Parte aggiunta per richiesta

    2

    Passo 2

    Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.

    3

    Passo 3

    Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.

    4

    Passo 4

    Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.