LC2D18G7
Schneider Electric
TeSys Deca IEC contactor, 18 A, 3 P, 10 HP at 480 VAC, reversing, 120 VAC 50/60 Hz coil
Disponibile
Richiedi un preventivo adesso
- "TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys D contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact |
| Minimum Switching Current | 5 mA for signalling circuit |
| Control Circuit Voltage Limits | 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Inrush Power In Va | 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Coil Technology | without built-in suppressor module |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Signalling Circuit Frequency | 25...400 Hz |
| Auxiliary Contacts Type | mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1 |
| Hold-In Power Consumption In Va | 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat Dissipation | 2-3 W 50/60 Hz |
| Product Certifications | DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA |
| Interlocking Type | mechanical |
| [Uc] Control Circuit Voltage | 120 V AC 50/60 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC |
| Power Dissipation Per Pole | 0.8 W AC-3 || 2.5 W AC-1 |
| Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit || 32 A (at 60 °C) for power circuit |
| Mounting Support | plate || rail |
| Control Circuit Type | AC 50/60 Hz |
| Standards | CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Contactor Application | resistive load || motor control |
| Rated Breaking Capacity | 300 A at 440 V for power circuit conforming to IEC 60947 |
| Product Or Component Type | reversing contactor |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947 |
| Product Name | TeSys Deca |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Connections - Terminals | control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit screw clamp terminals 1 1.5-6 mm²flexible without cable end || power circuit screw clamp terminals 2 1.5-6 mm²flexible without cable end || power circuit screw clamp terminals 1 1-6 mm²flexible with cable end || power circuit screw clamp terminals 2 1-4 mm²flexible with cable end || power circuit screw clamp terminals 1 1.5-6 mm²solid || power circuit screw clamp terminals 2 1.5-6 mm²solid |
| Range | TeSys || TeSys Deca |
| Pole Contact Composition | 3 NO |
| Device Presentation | preassembled with reversing power busbar |
| Utilisation Category | AC-3 || AC-1 |
| [Ie] Rated Operational Current | 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Tightening Torque | power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2 |
| Electrical Durability | 1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V |
| Mechanical Durability | 15 Mcycles |
| Poles Description | 3P |
| Operating Time | 12...22 ms closing || 4...19 ms opening |
| Overvoltage Category | III |
| Motor Power Kw | 4 kW at 220...230 V AC 50 Hz || 7.5 kW at 380...400 V AC 50 Hz || 9 kW at 415...440 V AC 50 Hz || 10 kW at 500 V AC 50 Hz || 10 kW at 660...690 V AC 50 Hz |
| Maximum Horse Power Rating | 1 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 5 hp at 200/208 V AC 60 Hz for 3 phase motors || 5 hp at 230/240 V AC 60 Hz for 3 phase motors || 10 hp at 460/480 V AC 60 Hz for 3 phase motors || 15 hp at 575/600 V AC 60 Hz for 3 phase motors |
| [Ui] Rated Insulation Voltage | power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL |
| Device Short Name | LC2D |
| [Icw] Rated Short-Time Withstand Current | 40 A 40 °C - 10 min for power circuit || 84 A 40 °C - 1 min for power circuit || 145 A 40 °C - 10 s for power circuit || 240 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit |
| Protective Cover | with |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews





