LC1K1610F7

Schneider Electric

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 16A, 1 NO aux., 110VAC coil

Disponibile

Richiedi un preventivo adesso

  • "TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7.5kW@400V). It provides a 110V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50\u00b0C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh)."
Per saperne di più arrow Weniger lesen arrow
Specification Value
Minimum Switching Current 5 mA for signalling circuit
Mechanical Robustness shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Uc] Control Circuit Voltage 110 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Height 58 mm
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO
Control Circuit Voltage Limits operational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
Non Overlap Distance 0.5 mm
[Ith] Conventional Free Air Thermal Current 20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Mounting Support rail || plate
Control Circuit Type AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for signalling circuit
Rated Breaking Capacity 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Irms Rated Making Capacity 160 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Motor Power Kw 4 kW 220...230 V AC 50/60 Hz AC-3 || 7.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 4 kW 220...230 V AC 50/60 Hz AC-3e || 7.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e || 4 kW 690 V AC 50/60 Hz AC-3e
Associated Fuse Rating 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
Net Weight 0.18 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV
Inrush Power In Va 30-30 VA (at 20 °C)
Connections - Terminals screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Pole Contact Composition 3 NO
Utilisation Category AC-3 || AC-3e
[Ie] Rated Operational Current 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Minimum Switching Voltage 17 V for signalling circuit
Maximum Operating Rate 3600 cyc/h
Signalling Circuit Frequency <= 400 Hz
Electrical Durability 1.3 Mcycles 16 A AC-3 <= 440 V || 1.3 Mcycles 16 A AC-3e <= 440 V
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type instantaneous 1 NO
Poles Description 3P
Hold-In Power Consumption In Va 4.5-4.5 VA (at 20 °C)
Operating Time 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Width 45 mm
Tightening Torque 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage Category III
Depth 57 mm
[Ui] Rated Insulation Voltage power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
[Icw] Rated Short-Time Withstand Current 115 A 50 °C - 1 s for power circuit || 105 A 50 °C - 5 s for power circuit || 100 A 50 °C - 10 s for power circuit || 75 A 50 °C - 30 s for power circuit || 55 A 50 °C - 1 min for power circuit || 50 A 50 °C - 3 min for power circuit || 25 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit
Heat Dissipation 1.3-1.3 W
Contactor Application motor control
Product Or Component Type contactor
Range TeSys
Device Application control
Device Short Name LC1K
Per saperne di più arrow Weniger lesen arrow
*Gli articoli nuovi sono coperti da una garanzia Obso di 24 mesi.
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.


“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
*La consegna e il ritiro il giorno stesso e successivo sono disponibili per le scorte delle nostre filiali nel Regno Unito e in Olanda. La consegna e il ritiro il giorno successivo e la consegna in 2 giorni sono disponibili per le scorte acquistate dai nostri partner. Nel 90% dei casi, se necessario, possiamo consegnare più velocemente del tempo previsto dal produttore.

Se necessario, sono disponibili anche opzioni standard per la consegna.


“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
Siamo accreditati ISO 9001 per garantire la tranquillità del vostro acquisto.

Cosa dicono di noi i nostri clienti

Trustpilot

1

Step 1

    Parte aggiunta per richiesta

    2

    Passo 2

    Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.

    3

    Passo 3

    Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.

    4

    Passo 4

    Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.