BSH0551T01F2A

Schneider Electric

AC servo motor BSH, Lexium 05, 0.5N.m, 8000rpm, untapped shaft, with brake, IP50

Disponibile

Richiedi un preventivo adesso

-

Specification Value
Circle Diameter Of The Mounting Holes 63 mm
Maximum Permanent Current 5.4 A
Continuous Power 0.45 W
Switching Frequency 8 kHz
Stator Electrical Time Constant 1.7 ms 20 °C
Holding Torque 0.8 N.m holding brake
Maximum Radial Force Fr 170 N 8000 rpm || 180 N 7000 rpm || 190 N 6000 rpm || 200 N 5000 rpm || 220 N 4000 rpm || 240 N 3000 rpm || 270 N 2000 rpm || 340 N 1000 rpm
Number Of Motor Stacks 1
Rotor Inertia 0.0803 kg.cm²
Number Of Motor Poles 6
Back Emf Constant 22 V/krpm 120 °C
Maximum Axial Force Fa 0.2 x Fr
Centring Collar Depth 2 mm
Second Shaft without second shaft end
Shaft Length 20 mm
Brake Pull-In Power 10 W
Phase three phase
Length 159 mm
Maximum Current Irms 6.2 A LXM15LD13M3 || 5.4 A LXM05CD10M2 || 5.4 A LXM05CD10M3X || 5.4 A LXM32.U90M2 || 4.5 A LXM32.U45M2 || 5.4 A LXM05AD10F1 || 5.4 A LXM05CU70M2 || 5.4 A LXM05AD10M2 || 5.4 A LXM05AD10M3X || 5.4 A LXM05BD10F1 || 5.4 A LXM05BD10M2 || 5.4 A LXM05BD10M3X || 5.4 A LXM05CD10F1
Net Weight 1.3 kg
Centring Collar Diameter 40 mm
Stator Inductance 20.8 mH 20 °C
Motor Flange Size 55 mm
[Us] Rated Supply Voltage 480 V
Number Of Mounting Holes 4
Shaft Diameter 9 mm
Mounting Holes Diameter 5.5 mm
Type Of Cooling natural convection
Feedback Type single turn SinCos Hiperface
Stator Resistance 12.2 Ohm 20 °C
Range Compatibility Lexium 05 || Lexium 15 || Lexium 32
Continuous Stall Current 1.4 A
Torque Constant 0.36 N.m/A 120 °C
Maximum Mechanical Speed 9000 rpm
Mounting Support international standard flange
Holding Brake with
Speed Feedback Resolution 131072 points/turn
Product Or Component Type servo motor
Nominal Output Power 150 W LXM32.U90M2 3 A, 115 V, single phase || 270 W LXM05AD10M3X, 200...240 V, three phase || 270 W LXM05BD10M3X, 200...240 V, three phase || 270 W LXM05CD10M3X, 200...240 V, three phase || 340 W LXM15LD13M3, 230 V, three phase || 300 W LXM32.U45M2 1.5 A, 230 V, single phase || 150 W LXM05AD10F1, 110...120 V, single phase || 150 W LXM05BD10F1, 110...120 V, single phase || 150 W LXM05CD10F1, 110...120 V, single phase || 150 W LXM05CU70M2, 200...240 V, single phase || 270 W LXM05AD10M2, 200...240 V, single phase || 270 W LXM05BD10M2, 200...240 V, single phase || 270 W LXM05CD10M2, 200...240 V, single phase
Peak Stall Torque 1.5 N.m LXM32.U90M2 3 A, 115 V, single phase || 1.24 N.m LXM15LD13M3, 230 V, three phase || 1.4 N.m LXM05AD10M3X, 200...240 V, three phase || 1.4 N.m LXM05BD10M3X, 200...240 V, three phase || 1.4 N.m LXM05CD10M3X, 200...240 V, three phase || 1.4 N.m LXM32.U45M2 1.5 A, 230 V, single phase || 1.08 N.m LXM05CU70M2, 200...240 V, single phase || 1.4 N.m LXM05AD10F1, 110...120 V, single phase || 1.4 N.m LXM05AD10M2, 200...240 V, single phase || 1.4 N.m LXM05BD10F1, 110...120 V, single phase || 1.4 N.m LXM05BD10M2, 200...240 V, single phase || 1.4 N.m LXM05CD10F1, 110...120 V, single phase || 1.4 N.m LXM05CD10M2, 200...240 V, single phase
Product Compatibility LXM05AD10F1 110...120 V single phase || LXM05AD10M3X 200...240 V three phase || LXM05BD10M3X 200...240 V three phase || LXM05CD10M3X 200...240 V three phase || LXM15LD13M3 230 V three phase || LXM05AD10M2 200...240 V single phase || LXM05BD10F1 110...120 V single phase || LXM05BD10M2 200...240 V single phase || LXM05CD10F1 110...120 V single phase || LXM05CD10M2 200...240 V single phase || LXM05CU70M2 200...240 V single phase || LXM32.U90M2 115 V single phase || LXM32.U45M2 230 V single phase
Ip Degree Of Protection IP50 standard
Shaft End untapped
Nominal Speed 3000 rpm LXM32.U90M2 3 A, 115 V, single phase || 6000 rpm LXM05AD10M3X, 200...240 V, three phase || 6000 rpm LXM05BD10M3X, 200...240 V, three phase || 6000 rpm LXM05CD10M3X, 200...240 V, three phase || 8000 rpm LXM15LD13M3, 230 V, three phase || 6000 rpm LXM32.U45M2 1.5 A, 230 V, single phase || 3000 rpm LXM05AD10F1, 110...120 V, single phase || 3000 rpm LXM05BD10F1, 110...120 V, single phase || 3000 rpm LXM05CD10F1, 110...120 V, single phase || 3000 rpm LXM05CU70M2, 200...240 V, single phase || 6000 rpm LXM05AD10M2, 200...240 V, single phase || 6000 rpm LXM05BD10M2, 200...240 V, single phase || 6000 rpm LXM05CD10M2, 200...240 V, single phase
Electrical Connection rotatable right-angled connectors
Nominal Torque 0.49 N.m LXM32.U90M2 3 A, 115 V, single phase || 0.41 N.m LXM15LD13M3, 230 V, three phase || 0.43 N.m LXM05AD10M3X, 200...240 V, three phase || 0.43 N.m LXM05BD10M3X, 200...240 V, three phase || 0.43 N.m LXM05CD10M3X, 200...240 V, three phase || 0.45 N.m LXM32.U45M2 1.5 A, 230 V, single phase || 0.43 N.m LXM05AD10M2, 200...240 V, single phase || 0.43 N.m LXM05BD10M2, 200...240 V, single phase || 0.43 N.m LXM05CD10M2, 200...240 V, single phase || 0.46 N.m LXM05AD10F1, 110...120 V, single phase || 0.46 N.m LXM05BD10F1, 110...120 V, single phase || 0.46 N.m LXM05CD10F1, 110...120 V, single phase || 0.46 N.m LXM05CU70M2, 200...240 V, single phase
Device Short Name BSH
Continuous Stall Torque 0.5 N.m LXM32.U90M2 3 A, 115 V, single phase || 0.5 N.m LXM15LD13M3, 230 V, three phase || 0.5 N.m LXM05AD10M3X, 200...240 V, three phase || 0.5 N.m LXM05BD10M3X, 200...240 V, three phase || 0.5 N.m LXM05CD10M3X, 200...240 V, three phase || 0.5 N.m LXM32.U45M2 1.5 A, 230 V, single phase || 0.5 N.m LXM05CU70M2, 200...240 V, single phase || 0.5 N.m LXM05AD10F1, 110...120 V, single phase || 0.5 N.m LXM05AD10M2, 200...240 V, single phase || 0.5 N.m LXM05BD10F1, 110...120 V, single phase || 0.5 N.m LXM05BD10M2, 200...240 V, single phase || 0.5 N.m LXM05CD10F1, 110...120 V, single phase || 0.5 N.m LXM05CD10M2, 200...240 V, single phase
Per saperne di più arrow Weniger lesen arrow
*Gli articoli nuovi sono coperti da una garanzia Obso di 24 mesi.
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.


“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
*La consegna e il ritiro il giorno stesso e successivo sono disponibili per le scorte delle nostre filiali nel Regno Unito e in Olanda. La consegna e il ritiro il giorno successivo e la consegna in 2 giorni sono disponibili per le scorte acquistate dai nostri partner. Nel 90% dei casi, se necessario, possiamo consegnare più velocemente del tempo previsto dal produttore.

Se necessario, sono disponibili anche opzioni standard per la consegna.


“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
Siamo accreditati ISO 9001 per garantire la tranquillità del vostro acquisto.

Cosa dicono di noi i nostri clienti

Trustpilot

1

Step 1

    Parte aggiunta per richiesta

    2

    Passo 2

    Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.

    3

    Passo 3

    Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.

    4

    Passo 4

    Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.