  • "TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 24 VDC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC."
Plus d'informations arrow Lire moins arrow
Specification Value
Contacts Type And Composition 1 NO + 1 NC fault signal || 3 NO
Height 61 mm
Connection Pitch 5.08 mm
Permissible Power 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Network And Machine Diagnosis Type fault recording || trip context information || waiting time after overload tripping || trip history information || running hours counter/operating time || motor control command recording || starting current and time || phase fault and earth fault trip counters || event recording || remaining operating time before overload tripping
Pollution Degree 3
Logic Input Number 6
Maximum Operating Rate 1800 cyc/h
Connections - Terminals control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
Input Current 7 mA
Current State 1 Guaranteed logic input < 15 V 2...15 mA 15 ms
Net Weight 0.53 kg
[Uimp] Rated Impulse Withstand Voltage 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Associated Fuse Rating 4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibility electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
Current State 0 Guaranteed logic input < 5 V <= 15 mA 5 ms
[Ui] Rated Insulation Voltage 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Short-Circuit Withstand 100 kA conforming to EN/IEC 60947-4-1
Compatibility Code LTMR
Protection Type locked rotor || overload || thermal overload protection || earth-leakage protection || reverse polarity protection || overload (long time) || power factor variation || phase unbalance || load fluctuation || phase failure || thermal protection
Web Services web server
Width 91 mm
Load Current 5 A 250 V AC logic output || 5 A 30 V DC logic output
Tightening Torque control circuit 0.5-0.6 N.m flat 3 mm
Overvoltage Category III
Depth 122.5 mm
Maximum Operating Frequency 2 Hz
Metering Type average current Iavg || earth-fault current || temperature || phase current I1, I2, I3 RMS || imbalance current
Product Or Component Type motor controller
Product Name TeSys T
Measurement Current 5-100 A
Range TeSys
Current Consumption 56...127 mA
[Us] Rated Supply Voltage 24 V DC
Communication Port Protocol Modbus TCP/EtherNet/IP
Bus Type Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs
Supply Voltage Limits 20.4-26.24 V DC
Device Application equipment monitoring and control
Device Short Name LTMR
Plus d'informations arrow Lire moins arrow
*Les articles neufs bénéficient d'une garantie Obso de 24 mois.
Nos articles d'occasion et nos options de réparation sont assortis d'une garantie Obso de 12 mois.


"Super service ! Tout a été traité très rapidement et avec compétence et l'assistance personnelle était excellente. Je choisirai toujours Obso Automation ! Merci beaucoup pour votre soutien." - MJ
*La livraison et l'enlèvement le jour même et le jour suivant sont disponibles pour les stocks de nos succursales au Royaume-Uni et aux Pays-Bas. La livraison et l'enlèvement le jour suivant et la livraison en deux jours sont disponibles pour les stocks provenant de nos partenaires. Dans 90% des cas, nous pouvons livrer plus rapidement que l'ETA du fabricant si nécessaire.

Des options de livraison standard sont également disponibles si nécessaire.


"Professionnel, courtois et précis. La pièce obsolète a fait l'objet d'un devis le jour même et a été livrée le lendemain" - PT
Nous sommes accrédités ISO 9001, ce qui vous permet d'acheter en toute tranquillité.

Qu'est-ce que nos clients disent de nous

Trustpilot

1

Step 1

    Partie ajoutée pour enquête

    2

    Étape 2

    Votre gestionnaire de compte personnel est déjà sur le coup et vous fournit des réponses rapides avec un service imbattable.

    3

    Étape 3

    Nous ne nous contentons pas de traiter les commandes, nous garantissons une livraison sans heurts, une transparence totale et une absence totale de maux de tête.

    4

    Étape 4

    Plus de 10 000 clients nous font confiance pour une bonne raison. Obtenez votre devis dès maintenant et découvrez l’automatisation sans risque, ni délai, ni incertitude.