GV2RT03
Schneider Electric
TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 0.25…0.40 A, screw clamp terminals
Disponible
Obtenez un devis maintenant
- "TeSys GV motor circuit breaker, 3 poles (3P), 0.4A/690V, for high starting current peak motor applications 0.06-0.09kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.25-0.40A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Line Rated Current | 0.4 A |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Height | 89 mm |
| Rated Duty | continuous IEC 60947-4-1 |
| Network Type | AC |
| Magnetic Tripping Current | 8-8 A |
| [Ith] Conventional Free Air Thermal Current | 0.4 A IEC 60947-4-1 |
| Motor Power Kw | 0.06-0.06 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.09-0.09 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.09-0.09 kW 440 V AC 50/60 Hz motor protection high peak current || 0.12-0.12 kW 440 V AC 50/60 Hz motor protection high peak current |
| Utilisation Category | category A IEC 60947-2 || AC-3 IEC 60947-4-1 |
| Fixing Mode | 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate) |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-2 |
| Control Type | toggle |
| Power Dissipation Per Pole | 2.5 W |
| Electrical Durability | 100000 cycles AC-3 415 V In |
| [Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Breaking Capacity | 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
| Suitability For Isolation | yes IEC 60947-1 § 7-1-6 |
| Thermal Protection Adjustment Range | 0.25-0.4 A IEC 60947-4-1 |
| Tightening Torque | 1.7 N.m screw clamp terminal |
| Mechanical Durability | 100000 cycles |
| Poles Description | 3P |
| Width | 45 mm |
| Depth | 78.5 mm |
| Network Frequency | 50/60 Hz IEC 60947-4-1 |
| Product Or Component Type | motor circuit breaker |
| Product Name | TeSys GV2 || TeSys Deca |
| Range | TeSys Deca |
| Device Application | motor protection || transformer |
| Device Short Name | GV2RT |
| Trip Unit Technology | thermal-magnetic |
Nos articles d'occasion et nos options de réparation sont assortis d'une garantie Obso de 12 mois.
"Super service ! Tout a été traité très rapidement et avec compétence et l'assistance personnelle était excellente. Je choisirai toujours Obso Automation ! Merci beaucoup pour votre soutien." - MJ
Des options de livraison standard sont également disponibles si nécessaire.
"Professionnel, courtois et précis. La pièce obsolète a fait l'objet d'un devis le jour même et a été livrée le lendemain" - PT
1
Step 1
Partie ajoutée pour enquête
2
Étape 2
Votre gestionnaire de compte personnel est déjà sur le coup et vous fournit des réponses rapides avec un service imbattable.
3
Étape 3
Nous ne nous contentons pas de traiter les commandes, nous garantissons une livraison sans heurts, une transparence totale et une absence totale de maux de tête.
4
Étape 4
Plus de 10 000 clients nous font confiance pour une bonne raison. Obtenez votre devis dès maintenant et découvrez l’automatisation sans risque, ni délai, ni incertitude.
Google Reviews