ATV340D22N4E
variable speed drive, Altivar Machine ATV340, 22kW, heavy duty, 400V, 3 phases, Ethernet
Disponible
Obtenez un devis maintenant
| Specification | Value |
|---|---|
| Prospective Line Isc | 22 kA |
| Power Dissipation In W | natural convection 28 W 380 V 4 kHz heavy duty) || forced convection 486 W 380 V 4 kHz heavy duty) || natural convection 39 W 380 V 4 kHz normal duty) || forced convection 631 W 380 V 4 kHz normal duty) |
| Line Current | 60.1 A 380 V normal duty) || 48.6 A 480 V normal duty) || 63.5 A 380 V heavy duty) || 50.6 A 480 V heavy duty) |
| Line Current | 63.5 A 380 V without line choke heavy duty) || 50.5 A 480 V without line choke heavy duty) || 67.9 A 480 V with external line choke normal duty) || 54.4 A 380 V with external line choke heavy duty) || 64.1 A 480 V with external line choke heavy duty) || 50.8 A 380 V with external line choke normal duty) |
| Analogue Output Type | software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits |
| Discrete Output Type | programmable output DQ1, DQ2 30 V DC 100 mA |
| Electrical Connection | screw terminal 0.2...2.5 mm² control || screw terminal 6...25 mm² motor || screw terminal 10...25 mm² line side || screw terminal 10...25 mm² DC bus |
| Asynchronous Motor Control Profile | optimized torque mode || constant torque standard || variable torque standard |
| Maximum Switching Current | relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| 4 Quadrant Operation Possible | true |
| Apparent Power | 45.1 kVA 480 V normal duty) || 42.1 kVA 480 V heavy duty) |
| Net Weight | 10.2 kg |
| With Safety Function Safe Direction (Sdi) | false |
| Type Of Polarization | no impedance |
| Relay Output Type | relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles |
| Switching Frequency | 2...16 kHz adjustable || 6...16 kHz with derating factor |
| Maximum Transient Current | 68.2 A 60 s normal duty) || 69 A 60 s heavy duty) || 83.7 A 2 s normal duty) || 83 A 2 s heavy duty) |
| Analogue Input Number | 2 |
| Motor Slip Compensation | automatic whatever the load || can be suppressed || adjustable || not available in permanent magnet motor law |
| Discrete Output Number | 2.0 |
| With Safety Function Safe Position (Sp) | false |
| Method Of Access | slave Modbus RTU || slave Modbus TCP |
| With Safety Function Safely Limited Position (Slp) | false |
| With Safety Function Safe Operating Stop (Sos) | false |
| Number Of Addresses | 1-247 |
| Discrete Input Number | 5 |
| With Sft Fct Safe Stop 2 (Ss2) | false |
| With Safety Function Safe Stop 1 (Ss1) | true |
| Width | 180.0 mm |
| Transmission Rate | 4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s |
| Depth | 249.0 mm |
| Analogue Input Type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits |
| Electrical Connection | control screw terminal 0.2...2.5 mm² AWG 24...AWG 12 || motor screw terminal 6...25 mm² AWG 8...AWG 3 || line side screw terminal 10...25 mm² AWG 6...AWG 3 || DC bus screw terminal 10...25 mm² AWG 6...AWG 3 |
| Maximum Output Frequency | 0.599 kHz |
| With Safety Function Safe Brake Management (Sbc/Sbt) | true |
| Height | 385.0 mm |
| Acceleration And Deceleration Ramps | S, U or customized || linear adjustable separately from 0.01...9999 s |
| Maximum Output Voltage | 480 V |
| Base Load Current At High Overload | 46.0 A |
| Transmission Frame | RTU |
| With Safety Function Safe Speed Monitor (Ssm) | false |
| Relay Output Number | 2 |
| With Safety Function Safe Torque Off (Sto) | true |
| Data Format | 8 bits, configurable odd, even or no parity |
| Base Load Current At Low Overload | 62.0 A |
| Connector Type | 3 RJ45 |
| Pollution Degree | 2 IEC 61800-5-1 |
| Analogue Output Number | 2 |
| Physical Interface | 2-wire RS 485 |
| Minimum Switching Current | relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC |
| Discrete Input Logic | 16 preset speeds |
| Continuous Output Current | 62 A 4 kHz normal duty || 46 A 4 kHz heavy duty |
| With Safety Function Safe Programmable Logic | false |
| Brake Chopper Integrated | true |
| Output Voltage | <= power supply voltage |
| Nominal Switching Frequency | 4 kHz |
| Braking To Standstill | by DC injection |
| Discrete Input Type | PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable |
| Protection Type | thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive |
| With Safety Function Safely Limited Speed (Sls) | true |
| Synchronous Motor Control Profile | permanent magnet motor || reluctance motor |
| Variant | standard version |
| Product Or Component Type | variable speed drive |
| Ip Degree Of Protection | IP20 |
| Phase | 3 phase |
| Communication Port Protocol | Modbus TCP || EtherNet/IP || Modbus serial |
| Nominal Output Current | 46.0 A |
| Product Specific Application | machine |
| Maximum Horse Power Rating | 40 hp normal duty || 30 hp heavy duty |
| Supply Frequency | 50...60 Hz +/- 5 % |
| Range Of Product | Altivar Machine ATV340 |
| Motor Power Kw | 30 kW normal duty || 22 kW heavy duty |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Mounting Mode | cabinet mount |
| Emc Filter | class C3 EMC filter integrated |
Nos articles d'occasion et nos options de réparation sont assortis d'une garantie Obso de 12 mois.
"Super service ! Tout a été traité très rapidement et avec compétence et l'assistance personnelle était excellente. Je choisirai toujours Obso Automation ! Merci beaucoup pour votre soutien." - MJ
Des options de livraison standard sont également disponibles si nécessaire.
"Professionnel, courtois et précis. La pièce obsolète a fait l'objet d'un devis le jour même et a été livrée le lendemain" - PT
1
Step 1
Partie ajoutée pour enquête
2
Étape 2
Votre gestionnaire de compte personnel est déjà sur le coup et vous fournit des réponses rapides avec un service imbattable.
3
Étape 3
Nous ne nous contentons pas de traiter les commandes, nous garantissons une livraison sans heurts, une transparence totale et une absence totale de maux de tête.
4
Étape 4
Plus de 10 000 clients nous font confiance pour une bonne raison. Obtenez votre devis dès maintenant et découvrez l’automatisation sans risque, ni délai, ni incertitude.
Google Reviews