- "TeSys K contactor, 3 poles (3NO), 9A/690V AC-3, for motor applications up to 4kW@400V. It provides a 220-230V 50/60Hz AC coil with rectifier incorporated and surge suppressor, 1NC built-in auxiliary contact, connection by screw clamp terminals. Silent contactor recommended for use in areas sensitive to noise and high interference mains supplies. Very compact, DIN-rail mounting and screw fixing, it procures reliability and durability to standard applications. Multi-standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach)."
| Specification | Value |
|---|---|
| Minimum Switching Current | 5 mA for signalling circuit |
| Mechanical Robustness | shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
| [Uc] Control Circuit Voltage | 220...230 V AC 50/60 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Auxiliary Contact Composition | 1 NC |
| Control Circuit Voltage Limits | operational: 0.85...1.1 Uc (at <50 °C) || drop-out: >= 0.10 Uc (at <50 °C) |
| Non Overlap Distance | 0.5 mm |
| [Ith] Conventional Free Air Thermal Current | 20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit |
| Mounting Support | rail || plate |
| Control Circuit Type | AC 50/60 Hz silent |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Rated Breaking Capacity | 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947 |
| Irms Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947 |
| Motor Power Kw | 2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/60 Hz AC-4 || 4 kW 380...415 V AC 50/60 Hz AC-4 || 4 kW 440/690 V AC 50/60 Hz AC-4 |
| Associated Fuse Rating | 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660 |
| Net Weight | 0.225 kg |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Inrush Power In Va | 3-3 VA (at 20 °C) |
| Connections - Terminals | screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end |
| Pole Contact Composition | 3 NO |
| Utilisation Category | AC-3 || AC-3e || AC-1 || AC-4 |
| [Ie] Rated Operational Current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Maximum Operating Rate | 3600 cyc/h |
| Signalling Circuit Frequency | <= 400 Hz |
| Electrical Durability | 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V |
| Mechanical Durability | 10 Mcycles |
| Auxiliary Contacts Type | instantaneous 1 NC |
| Poles Description | 3P |
| Hold-In Power Consumption In Va | 3-3 VA (at 20 °C) |
| Operating Time | 30...40 ms coil energisation and NO closing || 30 ms coil de-energisation and NO opening |
| Width | 45 mm |
| Tightening Torque | 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2 |
| Overvoltage Category | III |
| Depth | 57 mm |
| [Ui] Rated Insulation Voltage | power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14 |
| [Icw] Rated Short-Time Withstand Current | 90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit |
| Heat Dissipation | 3-3 W |
| Contactor Application | resistive load || motor control |
| Product Or Component Type | contactor |
| Range | TeSys |
| Device Application | control |
| Device Short Name | LC7K |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews