LP1D65008BD

Schneider Electric

IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style

Dostępny

Uzyskaj wycenę już teraz

  • "TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.17 inches deep. It weighs 4.89 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product."
Więcej informacji arrow Czytaj mniej arrow
Specification Value
Power Dissipation Per Pole 9.6 W AC-1
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current 80 A (at 60 °C) for power circuit
Control Circuit Voltage Limits 0.1...0.3 Uc -40-55 °C drop-out DC || 0.85...1.1 Uc -40-55 °C operational DC
Mounting Support plate || rail
Contact Compatibility M3
Control Circuit Type DC DC standard
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree 3
Hold-In Power Consumption In W 22-22 W 20 °C
Rated Breaking Capacity 1000 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity 1000 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Pole Contact Composition 2 NO + 2 NC
Connections - Terminals power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: solid || power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: solid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid
Coil Technology built-in bidirectional peak limiting diode suppressor
Time Constant 75 ms
Operating Time 4...19 ms opening || 12...26 ms closing
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 5 N.m screw clamp terminals 1-25 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Electrical Durability 1.5 Mcycles 80 A AC-1 <= 440 V
Mechanical Durability 10 Mcycles
Inrush Power In W 22-22 W 20 °C)
Compatibility Code LP1D
Overvoltage Category III
[Ui] Rated Insulation Voltage power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
[Icw] Rated Short-Time Withstand Current 110 A 40 °C - 10 min for power circuit || 260 A 40 °C - 1 min for power circuit || 520 A 40 °C - 10 s for power circuit || 900 A 40 °C - 1 s for power circuit
Protective Cover without
[Uc] Control Circuit Voltage 24 V DC
[Ue] Rated Operational Voltage power circuit <= 1000 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application resistive load
Product Or Component Type contactor
Range TeSys
Utilisation Category AC-1
[Ie] Rated Operational Current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Poles Description 4P
Device Short Name LP1D
Więcej informacji arrow Czytaj mniej arrow
*Nowe produkty są objęte 24-miesięczną gwarancją Obso.
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.


„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
*Dostawa i odbiór tego samego i następnego dnia są dostępne dla towarów z naszych oddziałów w Wielkiej Brytanii i Holandii. Odbiór następnego dnia i dostawa w ciągu 2 dni są dostępne dla towarów pochodzących od naszych partnerów. W 90% przypadków możemy dostarczyć towar szybciej niż przewidywany czas dostawy producenta.

W razie potrzeby dostępne są również standardowe opcje dostawy.


„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
Posiadamy akredytację ISO 9001, dzięki czemu możesz być spokojny o swój zakup.

Co mówią o nas nasi klienci

Trustpilot

1

Step 1

    Część dodana do zapytania

    2

    Krok 2

    Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.

    3

    Krok 3

    Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.

    4

    Krok 4

    Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.