LC1D95L6

Schneider Electric

Contactor, TeSys Deca, 3P 95A AC-3, <= 440V, aux 1NO+1NC, 200V AC 60Hz coil, screw clamp terminals

Dostępny

Uzyskaj wycenę już teraz

-

Specification Value
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current 5 mA for signalling circuit
Power Dissipation Per Pole 12.5 W AC-1 || 7.2 W AC-3
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit || 125 A (at 60 °C) for power circuit
Control Circuit Voltage Limits 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz || 0.85...1.1 Uc -40-55 °C operational AC 60 Hz || 1...1.1 Uc 55-70 °C operational AC 60 Hz
Mounting Support plate || rail
Control Circuit Type AC 60 Hz
Safety Reliability Level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 || B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for signalling circuit
Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 160 A gG at <= 690 V coordination type 2 for power circuit || 200 A gG at <= 690 V coordination type 1 for power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va 220-220 VA 60 Hz cos phi 0.75 (at 20 °C)
Pole Contact Composition 3 NO
Connections - Terminals control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 1 4-50 mm² - cable stiffness: rigid || power circuit: screw terminals 2 4-25 mm² - cable stiffness: rigid || power circuit: screw terminals 1 4-50 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 2 4-25 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 1 4-50 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 2 4-16 mm² - cable stiffness: flexible with cable end
Coil Technology without built-in suppressor module
Operating Time 20...35 ms closing || 6...20 ms opening
Minimum Switching Voltage 17 V for signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque control circuit 1.2 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminal Philips No 2 || power circuit 12 N.m screw terminal flat Ø 6 to Ø 8 mm || power circuit 12 N.m screw terminal hex (Allen key) 4 mm || control circuit 1.2 N.m screw clamp terminal pozidriv No 2
Electrical Durability 1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1
Mechanical Durability 10 Mcycles
Auxiliary Contacts Type mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Compatibility Code LC1D
Hold-In Power Consumption In Va 22-22 VA 60 Hz cos phi 0.3 (at 20 °C)
Overvoltage Category III
Maximum Horse Power Rating 7.5 hp at 115 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 25 hp at 200/208 V AC 60 Hz for 3 phase motors || 30 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Motor Power Kw 25 kW at 220...230 V AC 50 Hz (AC-3) || 45 kW at 380...400 V AC 50 Hz (AC-3) || 45 kW at 415...440 V AC 50 Hz (AC-3) || 55 kW at 500 V AC 50 Hz (AC-3) || 45 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 400 V AC 50 Hz (AC-4) || 25 kW at 220...230 V AC 50 Hz (AC-3e) || 45 kW at 380...400 V AC 50 Hz (AC-3e) || 45 kW at 415...440 V AC 50 Hz (AC-3e) || 55 kW at 500 V AC 50 Hz (AC-3e) || 45 kW at 660...690 V AC 50 Hz (AC-3e)
[Ui] Rated Insulation Voltage power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
[Icw] Rated Short-Time Withstand Current 1100 A 40 °C - 1 s for power circuit || 800 A 40 °C - 10 s for power circuit || 400 A 40 °C - 1 min for power circuit || 135 A 40 °C - 10 min for power circuit || 140 A - 100 ms for signalling circuit || 120 A - 500 ms for signalling circuit || 100 A - 1 s for signalling circuit
Heat Dissipation 6-10 W at 60 Hz for control circuit
Protective Cover with
[Uc] Control Circuit Voltage 200 V AC 60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application resistive load || motor control
Product Or Component Type contactor
Range TeSys
Utilisation Category AC-3 || AC-3e || AC-4 || AC-1
[Ie] Rated Operational Current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit || 125 A (at <60 °C) at <= 690 V AC-1 for power circuit
Poles Description 3P
Device Short Name LC1D
Więcej informacji arrow Czytaj mniej arrow
*Nowe produkty są objęte 24-miesięczną gwarancją Obso.
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.


„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
*Dostawa i odbiór tego samego i następnego dnia są dostępne dla towarów z naszych oddziałów w Wielkiej Brytanii i Holandii. Odbiór następnego dnia i dostawa w ciągu 2 dni są dostępne dla towarów pochodzących od naszych partnerów. W 90% przypadków możemy dostarczyć towar szybciej niż przewidywany czas dostawy producenta.

W razie potrzeby dostępne są również standardowe opcje dostawy.


„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
Posiadamy akredytację ISO 9001, dzięki czemu możesz być spokojny o swój zakup.

Co mówią o nas nasi klienci

Trustpilot

1

Step 1

    Część dodana do zapytania

    2

    Krok 2

    Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.

    3

    Krok 3

    Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.

    4

    Krok 4

    Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.