LC3D12AP7
TeSys Deca , star delta starter , 3 x 3P (3 NO) , 12 A , 230 V AC coil
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact |
| Minimum Switching Current | 5 mA for signalling circuit |
| Height | 124 mm |
| Control Circuit Voltage Limits | drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) || operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) || operational: 0.85...1.1 Uc at 60 Hz (at <60 °C) |
| Starting Time | 30 s |
| Net Weight | 1.53 kg |
| Inrush Power In Va | 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Connections - Terminals | power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end |
| Coil Technology | without built-in suppressor module |
| Maximum Operating Rate | 30 cyc/h 60 °C |
| Signalling Circuit Frequency | 25...400 Hz |
| Tightening Torque | power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 |
| Mechanical Durability | 15 Mcycles |
| Auxiliary Contacts Type | mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC |
| Hold-In Power Consumption In Va | 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Switching Voltage | 17 V signalling circuit |
| Width | 143 mm |
| Depth | 143 mm |
| Heat Dissipation | 2-3 W 50/60 Hz |
| Product Certifications | DNV || CSA || BV || LROS (Lloyds register of shipping) || CCC || RINA || GL || GOST || UL |
| Interlocking Type | mechanical |
| [Uc] Control Circuit Voltage | 230 V AC 50/60 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz |
| Standards | IEC 60947-5-1 || IEC 60947-4-1 || CSA C22.2 No 14 || EN 60947-5-1 || UL 508 || EN 60947-4-1 || IEC 60335-1 |
| Pole Contact Composition | 3 x 3 NO |
| Mounting Support | plate |
| Control Circuit Type | AC 50/60 Hz |
| Contactor Application | motor control |
| Product Or Component Type | star delta starter |
| Product Name | TeSys Deca |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Range | TeSys || TeSys Deca |
| Device Presentation | pre-wired |
| Utilisation Category | AC-3 |
| [Ie] Rated Operational Current | 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Auxiliary Contact Composition | 1 NC KM1 star contactor |
| Electrical Durability | 2 Mcycles 12 A AC-3 <= 440 V |
| Provided Equipment | protective cover |
| Overvoltage Category | III |
| Motor Power Kw | 11 kW 380/400 V AC 50/60 Hz || 11 kW 415 V AC 50/60 Hz || 11 kW 440 V AC 50/60 Hz || 5.5 kW 220/230 V AC 50/60 Hz |
| [Ui] Rated Insulation Voltage | power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL |
| Device Short Name | LC3D |
| Poles Description | 3 x 3P |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews