- "TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides 120V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60\u00b0C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact |
| Minimum Switching Current | 5 mA for signalling circuit |
| Control Circuit Voltage Limits | 0.1...0.3 Uc -40-70 °C drop-out DC || 0.8...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC |
| Hold-In Power Consumption In W | 2.4-2.4 W 20 °C |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Time Constant | 40 ms |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Signalling Circuit Frequency | 25...400 Hz |
| Inrush Power In W | 2.4-2.4 W 20 °C) |
| Auxiliary Contacts Type | mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1 |
| Product Certifications | DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA |
| Interlocking Type | mechanical |
| [Uc] Control Circuit Voltage | 12 V DC |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC |
| Power Dissipation Per Pole | 0.2 W AC-3 || 1.56 W AC-1 |
| Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit || 25 A (at 60 °C) for power circuit |
| Mounting Support | plate || rail |
| Control Circuit Type | DC low consumption |
| Standards | CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Contactor Application | resistive load || motor control |
| Rated Breaking Capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Product Or Component Type | reversing contactor |
| Irms Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Product Name | TeSys Deca |
| Associated Fuse Rating | 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Connections - Terminals | power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid || power circuit screw clamp terminals 2 1-4 mm²solid || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid |
| Range | TeSys || TeSys Deca |
| Pole Contact Composition | 3 NO |
| Device Presentation | preassembled with reversing power busbar |
| Utilisation Category | AC-1 || AC-3 |
| [Ie] Rated Operational Current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Tightening Torque | power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2 |
| Electrical Durability | 0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V |
| Mechanical Durability | 30 Mcycles |
| Poles Description | 3P |
| Operating Time | 65.45...88.55 ms closing || 20...30 ms opening |
| Overvoltage Category | III |
| Motor Power Kw | 2.2 kW at 220...230 V AC 50 Hz || 4 kW at 380...400 V AC 50 Hz || 4 kW at 415...440 V AC 50 Hz || 5.5 kW at 500 V AC 50 Hz || 5.5 kW at 660...690 V AC 50 Hz |
| Maximum Horse Power Rating | 0.5 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors |
| [Ui] Rated Insulation Voltage | power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL |
| Device Short Name | LC2D |
| [Icw] Rated Short-Time Withstand Current | 30 A 40 °C - 10 min for power circuit || 61 A 40 °C - 1 min for power circuit || 105 A 40 °C - 10 s for power circuit || 210 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit |
| Protective Cover | with |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews