ATV650D45N4EU

Schneider Electric

variable speed drive, Altivar Process ATV600, ATV650, 45kW, 400...480V, IP55

AVAILABLE

GET A QUOTE NOW

-

Specification Value
Prospective Line Isc 50 kA
Product Destination asynchronous motors || synchronous motors
Line Current 69.1 A 480 V normal duty) || 67.1 A 380 V heavy duty) || 59 A 480 V heavy duty) || 79.8 A 380 V normal duty)
Emc Filter integrated 50 m IEC 61800-3 category C2 || integrated 150 m IEC 61800-3 category C3
Asynchronous Motor Control Profile variable torque standard || constant torque standard || optimized torque mode
Variant with disconnect switch
Product Or Component Type variable speed drive
Apparent Power 49.1 kVA 480 V heavy duty) || 57.4 kVA 480 V normal duty)
Switching Frequency 4...12 kHz with derating factor || 2...12 kHz adjustable
Communication Port Protocol Ethernet || Modbus serial
Product Specific Application process and utilities
Safety Function STO (safe torque off) SIL 3
Maximum Horse Power Rating 50 hp heavy duty || 60 hp normal duty
Supply Frequency 50...60 Hz - 5...5 %
Option Card slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A communication module, CANopen screw terminals || slot A/slot B digital and analog I/O extension module || slot A/slot B output relay extension module || slot A communication module, Ethernet IP/Modbus TCP/MD-Link || communication module, BACnet MS/TP || communication module, Ethernet Powerlink || slot A communication module, Profibus DP V1
Degree Of Protection UL type 12 UL 508C
Range Of Product Altivar Process ATV600
Speed Drive Output Frequency 0.1-500 Hz
Ip Degree Of Protection IP55IEC 60529 || IP55IEC 61800-5-1
Motor Power Kw 37 kW heavy duty) || 45 kW normal duty)
[Us] Rated Supply Voltage 380...480 V
[Us] Rated Supply Voltage 380...480 V - 15...10 %
Discrete Input Logic 16 preset speeds
Type Of Cooling forced convection
Continuous Output Current 72 A 4 kHz heavy duty || 87 A 4 kHz normal duty
Nominal Switching Frequency 4 kHz
Device Short Name ATV650
Synchronous Motor Control Profile synchronous reluctance motor || permanent magnet motor
Discrete Input Logic positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Analogue Output Type software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Discrete Output Type relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA
Maximum Switching Current relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Exchange Mode half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Phase 3 phase
Net Weight 50 kg
Type Of Polarization no impedance
Relay Output Type configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Frequency Resolution analog input 0.012/50 Hz || display unit 0.1 Hz
Maximum Transient Current 111.8 A 60 s heavy duty) || 96.8 A 60 s normal duty)
Analogue Input Number 3
Motor Slip Compensation automatic whatever the load || adjustable || can be suppressed || not available in permanent magnet motor law
Discrete Output Number 0
Method Of Access slave Modbus TCP
Discrete Input Number 8
Local Signalling for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Linearity Error AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Number Of Addresses 1-247 Modbus serial
Width 290 mm
Transmission Rate 10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Depth 401 mm
Analogue Input Type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Sampling Duration 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Electrical Connection line side screw terminal 35...50 mm² || motor screw terminal 35...50 mm² || control removable screw terminals 0.5...1.5 mm²
Maximum Output Frequency 500 kHz
Height 910 mm
Acceleration And Deceleration Ramps linear adjustable separately from 0.01...9999 s
Transmission Frame RTU
Relay Output Number 3
Data Format 8 bits, configurable odd, even or no parity
Accuracy +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Connector Type RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Input Compatibility DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2
Permissible Temporary Current Boost 1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Mounting Mode wall mount
Analogue Output Number 2
Physical Interface Ethernet || 2-wire RS 485
Minimum Switching Current relay output R1, R2, R3 5 mA 24 V DC
Refresh Time relay output R1, R2, R3)5 ms +/- 0.5 ms)
Enclosure Mounting wall mounted
Isolation between power and control terminals
Output Voltage <= power supply voltage
Quantity Per Set 1
Braking To Standstill by DC injection
Discrete Input Type DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Protection Type safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive || thermal protection motor
Supply internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.