BMXDRC0805
Schneider Electric
discrete output module, Modicon X80, 8 NO or NC relay outputs, 24 to 240V AC, 24 to 125V DC
AVAILABLE
GET A QUOTE NOW
-
| Specification | Value |
|---|---|
| Range Of Product | Modicon X80 |
| Discrete Output Number | 8 EN/IEC 61131-2 |
| Discrete Output Logic | positive or negative |
| Discrete Output Voltage | 5...125 V 5...150 V DC || 24...240 V 19...264 V AC |
| Product Or Component Type | relay discrete output module |
| Mtbf Reliability | 2650000 H |
| Network Frequency | 50/60 Hz |
| Voltage Range | 5...150 V || 19...264 V |
| Minimum Switching Current | 10 mA 5 V DC |
| [Ith] Conventional Free Air Thermal Current | 4 A 40 °C || 3 A 50 °C || 2 A 60 °C |
| Status Led | 1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O |
| Insulation Resistance | > 10 MOhm 500 V DC |
| Network Frequency Limits | 47-63 Hz |
| Protection Type | external short-circuit protection || external overload protection || external overvoltage protection, inductive AC || external overvoltage protection, inductive DC |
| Power Dissipation In W | 3.6 W |
| Net Weight | 0.189 kg |
| Electrical Connection | 40 ways terminal block |
| Electrical Durability | AC-12 200000 cycles 48 VA 24 V 0-60 °C || AC-12 300000 cycles 48 VA 48 V 0-60 °C || AC-12 150000 cycles 96 VA 48 V 0-60 °C || AC-12 300000 cycles 110 VA 100...120 V 0-60 °C || AC-12 150000 cycles 220 VA 100...120 V 0-60 °C || AC-12 300000 cycles 220 VA 200...250 V 0-60 °C || AC-12 150000 cycles 500 VA 200...250 V 0-60 °C || AC-15 700000 cycles 10 VA 24 V 0-60 °C 0.4 ) || AC-15 500000 cycles 24 VA 24 V 0-60 °C 0.4 ) || AC-15 200000 cycles 48 VA 24 V 0-60 °C 0.4 ) || AC-15 700000 cycles 10 VA 48 V 0-60 °C 0.4 ) || AC-15 500000 cycles 24 VA 48 V 0-60 °C 0.4 ) || AC-15 300000 cycles 48 VA 48 V 0-60 °C 0.4 ) || AC-15 100000 cycles 96 VA 48 V 0-60 °C 0.4 ) || AC-15 1000000 cycles 10 VA 100...120 V 0-60 °C 0.4 ) || AC-15 300000 cycles 50 VA 100...120 V 0-60 °C 0.4 ) || AC-15 200000 cycles 110 VA 100...120 V 0-60 °C 0.4 ) || AC-15 70000 cycles 220 VA 100...120 V 0-60 °C 0.4 ) || AC-15 1000000 cycles 10 VA 200...250 V 0-60 °C 0.4 ) || AC-15 500000 cycles 50 VA 200...250 V 0-60 °C 0.4 ) || AC-15 200000 cycles 110 VA 200...250 V 0-60 °C 0.4 ) || AC-15 150000 cycles 220 VA 200...250 V 0-60 °C 0.4 ) || DC-12 200000 cycles 24 W 24 V 0-60 °C || DC-12 150000 cycles 48 W 24 V 0-60 °C || DC-12 150000 cycles 40 W 48...60 V 0-60 °C || DC-12 100000 cycles 45 W 100...125 V 0-60 °C || DC-13 100000 cycles 10 W 24 V 0-60 °C || DC-13 60000 cycles 24 W 24 V 0-60 °C || DC-13 40000 cycles 48 W 24 V 0-60 °C || DC-13 40000 cycles 40 W 48...60 V 0-60 °C || DC-13 100000 cycles 15 W 100...125 V 0-60 °C |
| Typical Current Consumption | 40 mA 3.3 V DC || 101 mA 24 V DC |
| Output Overvoltage Protection | use discharge diode on each output DC || use RC circuit on each output AC || use ZNO surge limiter on each output AC |
| Output Short-Circuit Protection | use 1 fast blow fuse per channel or group of channel |
| Output Overload Protection | use 1 fast blow fuse per channel or group of channel |
| Response Time On Output | <= 10 ms activation || <= 13 ms deactivation |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews